
Description
XMF Mobile fans with possibility of directing airflow.
Fan:
-
Sheet steel tubular casing.
-
Impeller in polyamide 6 reinforced with fibre glass
-
Protection guard against contacts, in accordance with standard UNE 100250, on both sides
-
Connection box with start-stop switch that can be rearmed manually to avoid switching the fan on accidentally (ISO 12100-2)
-
Airflow direction from motor to impeller
Motor:
-
Single-phase two-speed motors with IE-2 efficiency, except lower powers 0.75 kW.
-
Class F motors, with ball bearings and IP55 protection, except single-phase versions from size 35 to size 56, IP54 protection.
-
Single-phase 230V.-50Hz., and three-phase 230/400V.-50Hz.
-
Working temperature: -25°C. + 50°C
Finish:
- Anticorrosive finish in polyester resin, polymerised at 190°C, after alkaline degreasing and phosphate-free pre-treatment.
On request:
-
Airflow direction from impeller to motor
-
100% reversible impellers.
-
Special windings for different voltages
-
ATEX certification, Category 2
Sound Spectrum Analysis
2 measurementsSound Power dB(A)
Total: 89 LWASound Pressure dB(A)
Total: 71 LPA| Type | Unit | 63 Hz | 125 Hz | 250 Hz | 500 Hz | 1k Hz | 2k Hz | 4k Hz | 8k Hz | Total |
|---|---|---|---|---|---|---|---|---|---|---|
| Sound Power dB(A) | LWA | 42.0 | 59.0 | 71.0 | 79.0 | 84.0 | 84.0 | 80.0 | 73.0 | 89 |
| Sound Pressure dB(A) | LPA | 24.0 | 41.0 | 53.0 | 61.0 | 66.0 | 66.0 | 62.0 | 55.0 | 71 |